CHZWS - AF1855 IR FUSING FLUID
- MSDS: CHZWS
- Manufacturer: DEXTER CORP DEXTER ELECTRONIC MATERIALS DIV
- Product Name: AF1855 IR FUSING FLUID
- National Stock Number: 3439-00F056885
Product Identification
Product ID:AF1855 IR FUSING FLUID
MSDS Date:03/21/1997
FSC:3439
NIIN:00F056885
Status Code:A
MSDS Number: CHZWS
Responsible Party
INDUSTRY, CA 91746-5000
US
Emergency Phone: 818-916-9107
Info Phone: 818-968-6511
Cage: 79436
Contractor
Telephone: 818-968-6511
Cage: 12405
Ingredients
ISOPROPANOL (ISOPROPYL ALCOHOL), 2-PROPANOL, DIMETHYL
CAS: 67-63-0
RTECS: NT8050000
Fraction By Weight: 40-70%
OSHA PEL 400 PPM
ACGIH TLV: 400 PPM
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: MODERATE IRRITANT, BURNS W/LOSS
OF VISION. SKIN: SLIGHT IRRITANT. INHALATION: IRRITATING TO THE
EYES, NOSE, THROAT & LUNGS. INGESTION: IRRITATING TO MOUTH, STOMACH
& DIGESTIVE TRACT. MAY AFFECT THE LUNGS. HARMFUL.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION, REDNESS, PAIN, SINUS CONGESTION,
COUGHING, SHORTNESS OF BREATH, VOMITING, DROOLING
First Aid
First Aid:EYES: FLUSH W/FLOWING WATER FOR 10-15 MINS. BLINK FREQUENTLY.
SKIN: RINSE IMMEDIATELY W/PLENTY OF WATER. DON'T NEUTRALIZE
W/BASES. INHALATION: REMOVE TO FRESH AIR. GIVE CPR IF NEEDED.
INGESTION: DON'T INDUCE VOMITING. GIVE SMALL AMOUNTS OFWATER.
NEVER GIVE ANYTHING BY MOUTH IF UNCONSCIOUS. DON'T GIVE BASES.
OBTAIN MEDICAL ATTENTION IN ALL CASES.
Fire Fighting
Flash Point Method:COC
Flash Point:60F
Extinguishing Media:CO2, FOAM, DRY CHEMICALS, WATER SPRAY, FOG
Fire Fighting Procedures:WEAR SELF CONTAINED BREATHING APPARATUS
PRESSURE DEMAND MSHA/NIOSH & FULL FIRE FIGHTING PROTECTIVE GEAR.
Unusual Fire/Explosion Hazard:HEAT IN EXCESS OF FLASHPOINT, OPEN
FLAME/STORAGE W/INCOMPATIBLE MATERIALS.
Accidental Release
Spill Release Procedures:CLEAN-UP. REMOVE IGNITION SOURCES. PROVIDE
ADEQUATE VENTILATION/PERSONAL PROTECTIVE EQUIPMENT. ABSORB W/INERT
MATERIAL, THEN PLACE IN A CHEMICAL WASTE CONTAINER. PREVENT RUNOFF
TO STORM SEWERS, DITCHE S & OTHER PATHWAYS TO SOIL & WATERWAYS.
Handling
Handling and Storage Precautions:DON'T STORE W/INCOMPATIBLE MATERIALS.
STORE CONTAINERS UPRIGHT. KEEP AWAY FROM HEAT & FLAMES.
Other Precautions:AVOID BREATHING FUMES. DON'T SPLASH/SPILL.
Exposure Controls
Respiratory Protection:AN OSHA APPROVED AIR PURIFYING, HALF-FACE
RESPIRATOR SHOULD BE USED W/THE APPROPRIATE CARTRIDGE IF EXPOSURE
LIMITS ARE EXCEEDED.
Ventilation:USE LOCAL EXHAUST
Protective Gloves:CHEMICAL RESISTANT RUBBER
Eye Protection:SAFETY GLASSES W/SIDE SHIELDS/FACESHIELD
Other Protective Equipment:CHEMICAL RESISTANT APRON/BOOTS, SAFETY
SHOWER, EYE WASH STATION
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health
Chemical Properties
Boiling Pt:B.P. Text:177F
Spec Gravity:0.92
pH:2
Appearance and Odor:COLORLESS TO YELLOW W/ALCOHOL ODOR
Stability
Stability Indicator/Materials to Avoid:YES
OXIDIZERS
Stability Condition to Avoid:EXCESS HEAT, OPEN FLAME, EXTREME
TEMPERATURES
Hazardous Decomposition Products:CO, CO2, HYDROGEN CHLORIDE, OXIDES OF
CHLORINE
Disposal
Waste Disposal Methods:DISPOSE OF BY REUSE/REINTRODUCTION INTO THE
PROCESS, RECLAMATION, REGENERATION/RECYCLING, BURNING FOR
RECOVERY/INCINERATION, TREATMENT IAW/LOCAL, STATE & FEDERAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.